REACH regulation testing is the essential process for verifying that products and materials entering the European Union market comply with Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals. This guide explains the technical framework of REACH testing, including SVHC screening, Annex XVII restricted substance analysis, applicable sample types, and laboratory testing methods used by accredited third-party laboratories worldwide.
Technical Overview
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is a European Union regulation, formally cited as Regulation (EC) No 1907/2006, which entered into force on 1 June 2007. Administered by the European Chemicals Agency (ECHA), REACH establishes a comprehensive framework for managing chemical substances placed on the EU market, whether on their own, in mixtures, or within articles. For manufacturers, importers, and downstream users of consumer and industrial products, REACH regulation testing provides the analytical evidence needed to demonstrate compliance.
The regulatory structure of REACH rests on several key instruments. The Candidate List identifies Substances of Very High Concern (SVHCs), which include carcinogenic, mutagenic, and reprotoxic (CMR) substances, persistent, bioaccumulative, and toxic (PBT) substances, very persistent and very bioaccumulative (vPvB) substances, and endocrine disruptors. Annex XIV lists substances subject to authorisation, meaning they cannot be used after a specified sunset date unless an authorisation has been granted. Annex XVII imposes restrictions on the manufacture, placing on the market, and use of specific dangerous substances, mixtures, and articles. The Candidate List is updated approximately twice per year and now contains more than 240 entries, making periodic re-testing a practical necessity for sustained compliance.
Under Article 7(2) of REACH, producers and importers of articles containing an SVHC above 0.1% weight-by-weight (w/w) have a notification duty to ECHA. Article 33 additionally requires suppliers to communicate SVHC information down the supply chain and to consumers upon request. Furthermore, the Waste Framework Directive established the SCIP database, obliging companies to submit notifications for articles containing SVHCs above the 0.1% threshold. Laboratory testing is the most reliable means of generating the data required for these obligations.
Testing Samples
Electrical and Electronic Products
Consumer electronics, appliances, cables, chargers, batteries, and electronic components are frequently tested for SVHCs and restricted substances such as phthalate plasticizers, short-chain chlorinated paraffins (SCCPs), and flame retardants. Plastic housings, wire insulation, solder, and connectors are typical sampling points.
Toys and Childcare Articles
Toys are subject to strict limits for phthalates (DEHP, DBP, BBP, DIBP) under entry 51 of Annex XVII, as well as restrictions on certain aromatic amines derived from azo colorants. Sampling typically covers PVC components, paints, coatings, elastomers, and textile or leather elements.
Textiles, Footwear, and Apparel
Fabrics, yarns, sewing threads, prints, coatings, buttons, zippers, and trims are screened for restricted azo dyes, PFAS (per- and polyfluoroalkyl substances), formaldehyde, organotin compounds, polycyclic aromatic hydrocarbons (PAHs), and phthalates in plastisol prints and flexible components.
Leather Goods and Accessories
Leather materials in footwear, bags, belts, and gloves are tested for chromium VI (Cr(VI)), restricted under entry 47 of Annex XVII, along with azo dyes, PAHs in rubber components, and dimethyl fumarate (DMF).
Jewelry and Metal Products
Nickel-containing items in prolonged skin contact must comply with nickel release limits, verified using harmonized European methods. Lead and cadmium content in jewelry and metal accessories are also restricted under Annex XVII.
Packaging, Furniture, and Automotive Materials
Food-contact materials, packaging inks, furniture upholstery, foam padding, adhesives, sealants, and automotive interior components are tested for SVHCs such as flame retardants, bisphenol A, and formaldehyde-releasing agents.
Testing Items
REACH testing programs are generally organized around three tiers of regulatory scope:
- SVHC Candidate List screening — analytical screening covering the full current Candidate List (240+ substances), typically reported against the 0.1% w/w threshold per homogeneous material.
- Annex XVII restricted substances — substance-specific testing against concentration or migration/release limits, including phthalates (entries 51 and 52), cadmium (entry 23), lead in consumer articles (entry 63), nickel release (entry 27), PAHs (entry 50), Cr(VI) in leather (entry 47), organotin compounds (entry 20), azo colorants (entry 43), SCCPs (entry 41), formaldehyde, bisphenol A, PFOS and related PFAS restrictions, and ozone-depleting substances.
- Annex XIV and supporting analysis — verification of substances subject to authorisation where applicable to article production or imported mixtures.
Common analyte groups include phthalates and other plasticizers, heavy metals (lead, cadmium, mercury, chromium, arsenic), polycyclic aromatic hydrocarbons, brominated flame retardants (HBCDD, PBDEs), chlorinated paraffins, organotin compounds (TBT, DBT, MBT), bisphenols, alkylphenols and alkylphenol ethoxylates, per- and polyfluoroalkyl substances, azo dye precursors, and volatile organic compounds.
Testing Methods
Accredited third-party laboratories apply validated analytical chemistry methods, often aligned with published techniques from standards organizations, to quantify target substances in complex matrices. Typical instrumentation includes:
- GC-MS (gas chromatography–mass spectrometry) — phthalates, PAHs, SCCPs, azo dye cleavage products (after reduction), volatile organic compounds, and organotin derivatives (after derivatization).
- LC-MS / HPLC (liquid chromatography–mass spectrometry) — PFAS, bisphenol A, alkylphenol ethoxylates, and thermally labile compounds.
- ICP-MS / ICP-OES (inductively coupled plasma techniques) — total elemental determination of lead, cadmium, mercury, chromium, arsenic, and other metals after acid digestion.
- UV-Visible spectrophotometry — Cr(VI) in leather (aligned with ISO 17075) and formaldehyde extraction analysis (aligned with ISO 14184 for textiles).
- Migration and release testing — nickel release testing aligned with EN 1811 using synthetic sweat, and colorimetric azo screening aligned with EN 14362 series methods.
- XRF screening (X-ray fluorescence) — rapid preliminary screening for elemental composition to guide confirmatory wet-chemical analysis.
Because SVHCs are evaluated per homogeneous material, laboratory sample preparation involves careful disassembly and material separation. For SVHC screening, laboratories commonly apply a group-screening strategy in which representative analytes are quantified and results are extrapolated across structurally related substance groups, providing an efficient, technically defensible assessment of the entire Candidate List.
Applications
REACH regulation testing supports a broad range of commercial and regulatory objectives across global supply chains:
- EU market access — demonstrating compliance for imported articles, mixtures, and substances before customs clearance and placing on the market.
- SCIP database notifications — generating concentration data required for submissions to the ECHA SCIP database.
- Supply chain communication — fulfilling Article 33 duty to inform customers about SVHC content above 0.1% w/w.
- Restricted substances compliance programs — supporting corporate RSL (Restricted Substances List) management, supplier declarations, and material approval processes.
- Product development and material selection — verifying the chemical safety of new formulations, recycled materials, and alternative substances.
- Regulatory surveillance readiness — preparing technical documentation in anticipation of EU member state market surveillance actions.
FAQ
What is REACH regulation testing?
REACH testing is the laboratory analysis of products, components, and materials to determine whether they contain Substances of Very High Concern or Annex XVII restricted substances above regulatory limits. Results are used to demonstrate compliance with Regulation (EC) No 1907/2006 for goods placed on the EU market.
Who needs to perform REACH testing?
Manufacturers, importers, brand owners, and distributors of articles sold in the EU should verify chemical compliance through testing, particularly when articles contain plastics, coatings, textiles, leather, rubber, or metal finishes. Only the EU manufacturer or importer can register substances, but article suppliers outside the EU typically rely on accredited third-party laboratories to provide the analytical data their EU customers require.
What does the 0.1% w/w SVHC threshold mean?
The threshold applies to each homogeneous material in an article, not to the entire product. If any homogeneous material contains an SVHC at or above 0.1% by weight, supply chain communication obligations under Article 33, and potentially notification and SCIP duties, are triggered.
How often is the SVHC Candidate List updated?
ECHA updates the Candidate List approximately twice per year, typically in January and July. Because new substances are added continuously, products should be re-screened after each significant list update.
How long does REACH testing take?
Standard turnaround is typically five to ten working days for a routine SVHC screen or restricted substance panel, depending on the number of materials, analyte scope, and laboratory workload. Expedited services may shorten the timeline.
How does REACH differ from RoHS?
RoHS (Directive 2011/65/EU) restricts ten specific substances in electrical and electronic equipment, while REACH applies to virtually all articles and mixtures and covers a far larger universe of substances through the SVHC Candidate List, Annex XIV, and Annex XVII. Electrical products typically require compliance with both regulations.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time